    Parametric Modelling of EEG Data for the Identification of Mental Tasks

    Get PDF
    Electroencephalographic (EEG) data is widely used as a biosignal for the identification of different mental states in the human brain. EEG signals can be captured by relatively inexpensive equipment and acquisition procedures are non-invasive and not overly complicated. On the negative side, EEG signals are characterized by low signal-to-noise ratio and non-stationary characteristics, which makes the processing of such signals for the extraction of useful information a challenging task.peer-reviewe

    Parametric and Nonparametric EEG Analysis for the Evaluation of EEG Activity in Young Children with Controlled Epilepsy

    Get PDF
    There is an important evidence of differences in the EEG frequency spectrum of control subjects as compared to epileptic subjects. In particular, the study of children presents difficulties due to the early stages of brain development and the various forms of epilepsy indications. In this study, we consider children that developed epileptic crises in the past but without any other clinical, psychological, or visible neurophysiological findings. The aim of the paper is to develop reliable techniques for testing if such controlled epilepsy induces related spectral differences in the EEG. Spectral features extracted by using nonparametric, signal representation techniques (Fourier and wavelet transform) and a parametric, signal modeling technique (ARMA) are compared and their effect on the classification of the two groups is analyzed. The subjects performed two different tasks: a control (rest) task and a relatively difficult math task. The results show that spectral features extracted by modeling the EEG signals recorded from individual channels by an ARMA model give a higher discrimination between the two subject groups for the control task, where classification scores of up to 100% were obtained with a linear discriminant classifier

    Review on solving the inverse problem in EEG source analysis

    Get PDF
    In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a scalp potential recording. Furthermore, a review of the performance results of the different techniques is provided to compare these different inverse solutions. The authors also include the results of a Monte-Carlo analysis which they performed to compare four non parametric algorithms and hence contribute to what is presently recorded in the literature. An extensive list of references to the work of other researchers is also provided

    A decision support framework for the discrimination of children with controlled epilepsy based on EEG analysis

    Get PDF
    This work was supported in part by the EC-IST project Biopattern, contract no: 508803, by the EC ICT project TUMOR, contract no: 247754, by the University of Malta grant LBA-73-695, by an internal grant from the Technical University of Crete, ELKE# 80037 and by the Academy of Finland, project nos: 113572, 118355, 134767 and 213462.Background: In this work we consider hidden signs (biomarkers) in ongoing EEG activity expressing epileptic tendency, for otherwise normal brain operation. More specifically, this study considers children with controlled epilepsy where only a few seizures without complications were noted before starting medication and who showed no clinical or electrophysiological signs of brain dysfunction. We compare EEG recordings from controlled epileptic children with age-matched control children under two different operations, an eyes closed rest condition and a mathematical task. The aim of this study is to develop reliable techniques for the extraction of biomarkers from EEG that indicate the presence of minor neurophysiological signs in cases where no clinical or significant EEG abnormalities are observed. Methods: We compare two different approaches for localizing activity differences and retrieving relevant information for classifying the two groups. The first approach focuses on power spectrum analysis whereas the second approach analyzes the functional coupling of cortical assemblies using linear synchronization techniques. Results: Differences could be detected during the control (rest) task, but not on the more demanding mathematical task. The spectral markers provide better diagnostic ability than their synchronization counterparts, even though a combination (or fusion) of both is needed for efficient classification of subjects. Conclusions: Based on these differences, the study proposes concrete biomarkers that can be used in a decision support system for clinical validation. Fusion of selected biomarkers in the Theta and Alpha bands resulted in an increase of the classification score up to 80% during the rest condition. No significant discrimination was achieved during the performance of a mathematical subtraction task.peer-reviewe

    Comparison of single trial back-projected independent components with the averaged waveform for the extraction of biomarkers of auditory P300 EPs

    Get PDF
    The independent components analysis (ICA) of the auditory P300 evoked responses in the EEG of normal subjects is described. The purpose was to identify any features which might provide the basis for biomarkers for diseases, such as Alzheimer’s disease. Single trial P300s were analysed by ICA, the activations were back-projected to scalp electrodes, many artefactual components were removed automatically, and the back-projected independent components (BICs) were first clustered according to their amplitudes and latencies. Then these primary clusters were secondarily clustered according to the columns of their mixing matrices, which clusters together those BICs with the same scalp topographies and, therefore, source locations. The BICs comprising the P300s had simple shapes, approximating half-sinusoids. Trial- to-trial variations in the BICs were found, which explain why different averages have been reported. Both positive- and also negative-going BICs were identified, some associated with known peaks in the P300 waveform. Artefact-free, single trial P300 waveforms could be constructed from the BICs, but these are probably of less interest than the BICs themselves. The findings demonstrate that neither averaged P300s, nor single trial P300s, are reliable as biomarkers, but rather it will be necessary to investigate the BICs present in a number of single trial realizations.peer-reviewe

    To extract the independent components of the evoked potentials in the EEG using ICA

    Get PDF
    The aim was to develop a reliable method of extracting the independent components of single trial evoked potential (EP) signals to derive features for the subject’s bioprofile, for diagnostic, prognostic, and monitoring purposes. Single trials are of interest, because conventional averaging conceals trial-to-trial variability and hence information. Independent Components Analysis (ICA) is a technique for Blind Source Separation (BSS) to recover N temporally independent source signals s = {s1(t), ... sN(t)} from N linear mixtures (the observations), x = {x1(t), ... xN(t)} obtained by multiplying the matrix of unknown sources s by an unknown mixing matrix A, (x = A.s). ICA seeks a square unmixing matrix W such that s = W.x. Difficulties arise for short duration, relatively low amplitude EPs, which have sparse ICs. The effectiveness of different algorithms was compared. Problems associated with more sources than measurement electrodes and with the generation by the algorithms of artefactual components were investigated. Ways of extracting the true EP components were considered. Component grouping was applied to obtain reliable groups, which could be explored for any clinical interpretations. Here we describe the recommended approach as developed by our virtual research group.peer-reviewe

    Multiorgan MRI findings after hospitalisation with COVID-19 in the UK (C-MORE): a prospective, multicentre, observational cohort study

    Get PDF
    Introduction: The multiorgan impact of moderate to severe coronavirus infections in the post-acute phase is still poorly understood. We aimed to evaluate the excess burden of multiorgan abnormalities after hospitalisation with COVID-19, evaluate their determinants, and explore associations with patient-related outcome measures. Methods: In a prospective, UK-wide, multicentre MRI follow-up study (C-MORE), adults (aged ≥18 years) discharged from hospital following COVID-19 who were included in Tier 2 of the Post-hospitalisation COVID-19 study (PHOSP-COVID) and contemporary controls with no evidence of previous COVID-19 (SARS-CoV-2 nucleocapsid antibody negative) underwent multiorgan MRI (lungs, heart, brain, liver, and kidneys) with quantitative and qualitative assessment of images and clinical adjudication when relevant. Individuals with end-stage renal failure or contraindications to MRI were excluded. Participants also underwent detailed recording of symptoms, and physiological and biochemical tests. The primary outcome was the excess burden of multiorgan abnormalities (two or more organs) relative to controls, with further adjustments for potential confounders. The C-MORE study is ongoing and is registered with ClinicalTrials.gov, NCT04510025. Findings: Of 2710 participants in Tier 2 of PHOSP-COVID, 531 were recruited across 13 UK-wide C-MORE sites. After exclusions, 259 C-MORE patients (mean age 57 years [SD 12]; 158 [61%] male and 101 [39%] female) who were discharged from hospital with PCR-confirmed or clinically diagnosed COVID-19 between March 1, 2020, and Nov 1, 2021, and 52 non-COVID-19 controls from the community (mean age 49 years [SD 14]; 30 [58%] male and 22 [42%] female) were included in the analysis. Patients were assessed at a median of 5·0 months (IQR 4·2–6·3) after hospital discharge. Compared with non-COVID-19 controls, patients were older, living with more obesity, and had more comorbidities. Multiorgan abnormalities on MRI were more frequent in patients than in controls (157 [61%] of 259 vs 14 [27%] of 52; p<0·0001) and independently associated with COVID-19 status (odds ratio [OR] 2·9 [95% CI 1·5–5·8]; padjusted=0·0023) after adjusting for relevant confounders. Compared with controls, patients were more likely to have MRI evidence of lung abnormalities (p=0·0001; parenchymal abnormalities), brain abnormalities (p<0·0001; more white matter hyperintensities and regional brain volume reduction), and kidney abnormalities (p=0·014; lower medullary T1 and loss of corticomedullary differentiation), whereas cardiac and liver MRI abnormalities were similar between patients and controls. Patients with multiorgan abnormalities were older (difference in mean age 7 years [95% CI 4–10]; mean age of 59·8 years [SD 11·7] with multiorgan abnormalities vs mean age of 52·8 years [11·9] without multiorgan abnormalities; p<0·0001), more likely to have three or more comorbidities (OR 2·47 [1·32–4·82]; padjusted=0·0059), and more likely to have a more severe acute infection (acute CRP >5mg/L, OR 3·55 [1·23–11·88]; padjusted=0·025) than those without multiorgan abnormalities. Presence of lung MRI abnormalities was associated with a two-fold higher risk of chest tightness, and multiorgan MRI abnormalities were associated with severe and very severe persistent physical and mental health impairment (PHOSP-COVID symptom clusters) after hospitalisation. Interpretation: After hospitalisation for COVID-19, people are at risk of multiorgan abnormalities in the medium term. Our findings emphasise the need for proactive multidisciplinary care pathways, with the potential for imaging to guide surveillance frequency and therapeutic stratification

    The independent components of auditory P300 and CNV evoked potentials derived from single-trial recordings.

    No full text
    The back-projected independent components (BICs) of single-trial, auditory P300 and contingent negative variation (CNV) evoked potentials (EPs) were derived using independent component analysis (ICA) and cluster analysis. The method was tested in simulation including a study of the electric dipole equivalents of the signal sources. P300 data were obtained from healthy and Alzheimer's disease (AD) subjects. The BICs were of approximately 100 ms duration and approximated positive- and negative-going half-sinusoids. Some positively and negatively peaking BICs constituting the P300 coincided with known peaks in the averaged P300. However, there were trial-to-trial differences in their occurrences, particularly where a positive or a negative BIC could occur with the same latency in different trials, a fact which would be obscured by averaging them. These variations resulted in marked differences in the shapes of the reconstructed, artefact-free, single-trial P300s. The latencies of the BIC associated with the P3b peak differed between healthy and AD subjects (p < 0.01). More reliable evidence than that obtainable from single-trial or averaged P300s is likely to be found by studying the properties of the BICs over a number of trials. For the CNV, BICs corresponding to both the orienting and the expectancy components were found